Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
Motriz (Online) ; 28: e10220016321, 2022. tab, graf
Article in English | LILACS | ID: biblio-1386374

ABSTRACT

Abstract Aim: This study aims to compare the sleep parameters in Paralympic powerlifting athletes during days with and without training, and to analyze the relationship between the training load and sleep on the same day and the relationship between the previous night's sleep and the training load of the following day. Methods: Actigraphy was used to analyze the sleep parameters of 11 Paralympic powerlifting athletes for 14 days (7 days without and with training), whereas Ratings of Perceived Exertion (RPE) analysis was used to assess training load. In addition, the Horne and östberg chronotype questionnaire and the Epworth Sleepiness Scale were applied. Results: Athletes show morning and indifferent chronotype and low daytime sleepiness. We found that on training days, sleep onset latency (SOL) was lower (average 5.3 min faster), whereas total sleep time (TST) and sleep efficiency (SE) were higher (TST averaged 169 min and SE 7% higher) compared to non-training days. In addition, the TST of the night before the training days correlated positively with the RPE of the following day, and the training volume correlated negatively with the SE of the same day. Conclusion: Our findings show that Paralympic powerlifting training had positive effects in increasing TST and SE and decreasing SOL on training days. These results show the positive effects of this type of training in improving sleep in athletes with physical disabilities. In addition, a good night's sleep the day before training can make it possible to put more effort into the next day's training. Therefore, guiding athletes to sleep more before training with more intense loads is recommended.


Subject(s)
Humans , Sleep , Sports for Persons with Disabilities , Endurance Training , Para-Athletes , Actigraphy/instrumentation
2.
Pesqui. vet. bras ; 37(12): 1491-1498, dez. 2017. ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-895381

ABSTRACT

As afecções ortopédicas com perda de tecido ósseo são um desafio não só na medicina veterinária mas também na medicina humana. Analisou a interface entre compósito, constituído de esferas de quitosana e polimetilmetacrilato em falha óssea (leito receptor) de tíbia de coelhos, por meio de técnica radiológica, avaliação macroscópica e pela microscopia eletrônica de varredura, em diferentes tempos. Foram utilizados 12 coelhos adultos da raça Nova Zelândia, divididos em quatro Grupos Experimentais (E1, n=3; E2, n=3; E3, n=3 e E4, n=3), que tiveram as falhas ósseas das tibiais direitas preenchidas com compósito, e avaliadas no pós-operatório imediato, aos 30, 60 e 90 e 120 dias. Dos compósitos implantados nas tíbias de coelhos, apenas dois permaneceram em seus leitos receptores, enquanto que os demais se encontravam encapsulados no tecido subcutâneo. As esferas de quitosana, presentes nas superfícies dos biomateriais implantados, que mantiveram contato direto com o leito receptor de tíbias de coelhos apresentavam-se preservadas e não integraram ao tecido ósseo. Diante disso, para melhor compreensão do comportamento da quitosana como substituto ósseo, novas pesquisas serão necessárias.(AU)


Orthopedic diseases with bone loss are challenging in both veterinary and human medicine. The aim of this investigation was to analyze and compare the reactions at the interface between the composite, made of chitosan and polymethylmethacrylate, and the bone defect (receptor site) of the rabbits tibia through radiological and microscopic techniques and by scanning electron microscopy, in different periods. Twelve adult New Zealand rabbits were divided into four experimental groups (E1, n=3; E2, n=3; E3, n=3 and E4, n=3), which had the right tibial bone defects filled with the composite, and evaluated in the immediate postoperative, 30, 60, 90 and 120 days. Composite implanted in the tibia of rabbits, only two remained in their beds receivers, while the remaining were encapsulated in the subcutaneous tissue. Spheres of chitosan present in the biomaterial that has been deployed and were in direct contact with the bone defect, were preserved, however, were not integrated into the bone tissue. Therefore, to understand the behavior of chitosan as a bone substitute, further research is needed.(AU)


Subject(s)
Animals , Rabbits , Tibia/surgery , Tibial Fractures/veterinary , Composite Resins , Bone Substitutes/analysis , Polymethyl Methacrylate , Chitosan
3.
Pesqui. vet. bras ; 34(9): 822-826, set. 2014. graf
Article in English | LILACS, VETINDEX | ID: lil-728817

ABSTRACT

The aim of this study was to evaluate the preventive effect of sodium bicarbonate on systemic acidosis due to ruminal acidosis, which was induced by ingestion of concentrate after prolonged fasting. Fourteen sheep were divided into three experimental groups: control group (Cg), with four sheep, submitted to fasting without development of ruminal acidosis; no-treated group (NTg), with five sheep with rumen acidosis without preventive treatment; and treated group (Tg), with five sheep with rumen acidosis and preventively treated with sodium bicarbonate. Assessments of ruminal pH and arterial hemogasometry were performed for 48 hours after ingestion of the concentrate. There was a reduction in the ruminal pH in all groups, whereas the Cg showed a reduction only after 24 hours. A reduction in the arterial pH, bicarbonate and base excess in all groups was also noted, indicating systemic metabolic acidosis, but the NTg presented the greatest alteration. It is concluded that sodium bicarbonate prevents systemic metabolic acidosis, reducing its severity in sheep subjected to ruminal acidosis.(AU)


O objetivo deste estudo foi avaliar o efeito preventivo do bicarbonato de sódio sobre a acidose sistêmica em decorrência da acidose ruminal, a qual foi induzida pelo fornecimento de concentrado após jejum prolongado. Foram utilizados 14 ovinos, divididos em três grupos experimentais: grupo controle (Cg), contendo quatro ovinos, submetidos a jejum sem desenvolvimento de acidose ruminal; grupo não tratado (NTg), contendo cinco ovinos submetidos a acidose ruminal sem tratamento preventivo; e grupo tratado (Tg), contendo cinco ovinos, submetidos a acidose ruminal e tratados preventivamente com bicarbonato de sódio. Foram realizadas avaliações do pH ruminal e hemogasometria arterial, durante 48 horas após o fornecimento do concentrado. Houve redução do pH ruminal em todos os grupos, sendo que o Cg apresentou a redução apenas às 24 horas. Notou-se redução do pH arterial, bicarbonato e excesso de base em todos os grupos, indicando acidose metabólica sistêmica; no entanto, o NTg apresentou o quadro mais grave. Conclui-se que o bicarbonato de sódio possui efeito preventivo da acidose metabólica sistêmica, reduzindo a sua gravidade em ovinos submetidos à acidose ruminal.(AU)


Subject(s)
Animals , Acidosis/veterinary , Sheep/metabolism , Sodium Bicarbonate/therapeutic use
4.
Pesqui. vet. bras ; 34(2): 173-178, fev. 2014. ilus
Article in Portuguese | LILACS | ID: lil-709862

ABSTRACT

Foi realizada falha segmentar com 6mm de diâmetro na região metafisária medial de tíbias de 12 coelhos, onde foi implantado uma associação de micro e macrofragmentos de matriz óssea cortical heteróloga fragmentada conservada em glicerina (98%) e polimetilmetacrilato autoclavados, para a sua reconstrução, e avaliados radiológica e macroscopicamente aos 30, 60, 90 e 120 dias. Houve adesão, em relação ao tempo, dos micro e macrocompósitos ao leito receptor, em 100% dos casos, mostrando ser biologicamente biocompatível, pois promoveram a reparação de falhas ósseas, sem sinais de infecção, migração e/ou rejeição, podendo, dessa forma, ser mais uma opção como substituto para preencher grandes defeitos ósseos.


A segmental defect of 6mm diameter was performed in the medial metaphyseal region of the tibia of 12 rabbits. For the bone defect reconstruction there was implanted a combination of micro and macro fragments of heterologous fragmented cortical bone matrix preserved in glycerin (98%) and polymethylmethacrylate, both autoclaved. Radiological and macroscopic evaluation was performed at 30, 60, 90 and 120 days. Adhesion in relation to time of the micro and macro composites to the recipient bed was observed in 100% of the cases. This showed that this implant is biologically biocompatible, since it promoted bone defects repair, with no signs of infection, migration and/or rejection. In this way, this implant can be classified as one more option of substitute to fill large bone defects.


Subject(s)
Animals , Bone Matrix , Rabbits/injuries , Polymethyl Methacrylate/therapeutic use , Tibia/injuries , Biocompatible Materials/therapeutic use , Technology, Radiologic
5.
Pesqui. vet. bras ; 33(6): 765-770, June 2013. ilus
Article in Portuguese | LILACS | ID: lil-680793

ABSTRACT

Os traumas que resultam em fraturas ósseas, principalmente as cominutivas, têm uma importância muito grande na rotina clínico-cirúrgica veterinária e humana. Foi realizada falha segmentar de 6mm na região metafisária medial da tíbia esquerda de 12 coelhos, a qual foi preenchida com implante constituído de matriz óssea mineralizada heteróloga fragmentada e metilmetacrilato, preservados em glicerina (98%) para a sua reconstrução. Foi realizada avaliação morfológica e radiológica aos 30, 60, 90 e 120 dias e observou-se a incorporação do implante ao leito receptor, em 100% dos casos, mostrando ser biologicamente compatível, pois promoveu a reparação das falhas ósseas, sem sinais de infecção, migração e/ou rejeição, sendo uma opção de substituto para preencher defeitos ósseos.


The traumas that result in bone fractures, especially comminuted, have high importance in veterinary and human surgical routine. A 6mm of segmental defect was performed at the medial metaphyseal region of the left tibia of 12 rabbits and an association of fragmented heterologue mineralized bone matrix and methylmethacrylate conserved in glycerin (98%) was used as a graft to fill the bone defect. To evaluate the procedure morphological and radiological exams were performed after 30, 60, 90 and 120 days. There was gradual integration of the bone graft in the receptor bed in 100% of the cases showing that the material is biologically compatible as it promotes bone defect reparation without signs of infection, migration and/or rejection and can be considered one more option to be used as a substitute to fill bone defects.


Subject(s)
Animals , Bone Matrix/injuries , Bone Matrix , Osseointegration , Orthopedics/veterinary , Rabbits , Radiography , Radiography/veterinary , Glycerol/chemistry , Methylmethacrylate/analysis
SELECTION OF CITATIONS
SEARCH DETAIL